Lochinvar & A.O. Smith 100111058 Outlet Switch
Maintain the safety and operational integrity of commercial water heating systems with the Lochinvar & A.O. Smith 100111058 Blocked Outlet Switch. This genuine OEM safety control is engineered to monitor exhaust vent conditions in high-efficiency appliances, including the BTH, SUF, and HCG Series. Functioning as a critical pressure sensing switch, it detects obstructions in the exhaust path and immediately triggers a system shutdown to prevent the accumulation of flue gases or dangerous overheating. Designed specifically for commercial gas water heaters, this 100111058 air pressure switch is compatible with Series 100-250 Natural Gas units and Series 100-199 Propane models. As a veterans' choice for field repairs, this replacement water heater switch (also identified as part 9006282015) ensures that your exhaust vent safety protocols remain compliant with manufacturer specifications. Rely on OEM HVAC controls to restore peak performance and ensure precise blocked outlet detection in demanding mechanical environments.
Key Benefits:- Precise Pressure Monitoring: Actively senses vent obstructions to maintain safe combustion cycles.
- Extensive Compatibility: Fits a broad range of Lochinvar and A.O. Smith Cyclone commercial models.
- Rugged Construction: Built for the thermal demands of high-output gas-fired equipment.
- Direct OEM Replacement: Ensures seamless fitment and electrical alignment with existing wiring harnesses.
What are the signs that a blocked outlet switch has failed?
Technicians typically observe a specific error code on the digital controller indicating a "Blocked Outlet" or "Pressure Switch Open" fault, even if the venting appears clear. This often points to a diaphragm failure or electrical continuity issue within the switch.
Is the 100111058 compatible with both LP and Natural Gas units?
Yes, this switch is designed for use in BTH/SUF/HCG units ranging from 100,000 to 250,000 BTU for Natural Gas and up to 199,000 BTU for Propane (LP) configurations.
Can I use an aftermarket universal switch instead?
For commercial safety circuits, it is highly recommended to use the genuine A.O. Smith 100111058. Calibration points for blocked outlet detection are specific to the blower and vent assembly; using an incorrect part can lead to nuisance tripping or unsafe operating conditions.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Original: $97.18
-65%$97.18
$34.01Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Maintain the safety and operational integrity of commercial water heating systems with the Lochinvar & A.O. Smith 100111058 Blocked Outlet Switch. This genuine OEM safety control is engineered to monitor exhaust vent conditions in high-efficiency appliances, including the BTH, SUF, and HCG Series. Functioning as a critical pressure sensing switch, it detects obstructions in the exhaust path and immediately triggers a system shutdown to prevent the accumulation of flue gases or dangerous overheating. Designed specifically for commercial gas water heaters, this 100111058 air pressure switch is compatible with Series 100-250 Natural Gas units and Series 100-199 Propane models. As a veterans' choice for field repairs, this replacement water heater switch (also identified as part 9006282015) ensures that your exhaust vent safety protocols remain compliant with manufacturer specifications. Rely on OEM HVAC controls to restore peak performance and ensure precise blocked outlet detection in demanding mechanical environments.
Key Benefits:- Precise Pressure Monitoring: Actively senses vent obstructions to maintain safe combustion cycles.
- Extensive Compatibility: Fits a broad range of Lochinvar and A.O. Smith Cyclone commercial models.
- Rugged Construction: Built for the thermal demands of high-output gas-fired equipment.
- Direct OEM Replacement: Ensures seamless fitment and electrical alignment with existing wiring harnesses.
What are the signs that a blocked outlet switch has failed?
Technicians typically observe a specific error code on the digital controller indicating a "Blocked Outlet" or "Pressure Switch Open" fault, even if the venting appears clear. This often points to a diaphragm failure or electrical continuity issue within the switch.
Is the 100111058 compatible with both LP and Natural Gas units?
Yes, this switch is designed for use in BTH/SUF/HCG units ranging from 100,000 to 250,000 BTU for Natural Gas and up to 199,000 BTU for Propane (LP) configurations.
Can I use an aftermarket universal switch instead?
For commercial safety circuits, it is highly recommended to use the genuine A.O. Smith 100111058. Calibration points for blocked outlet detection are specific to the blower and vent assembly; using an incorrect part can lead to nuisance tripping or unsafe operating conditions.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.