When you are dialing in a Nordyne or Miller split system, the Nordyne 664058 is the specific .058 restrictor orifice required to maintain precise refrigerant metering. As a veteran in the field, you know that using the wrong flow restrictor #58 results in immediate superheat issues, either flooding the evaporator or starving the coil. This piston-style metering device is engineered for specific tonnage and SEER pairings, ensuring the pressure drop across the liquid line stays within OEM parameters. Fabricated from high-grade brass to resist pitting and debris accumulation, this HVAC orifice plate provides the reliable, fixed-metering performance necessary for systems where a TXV is not utilized. Whether you are performing a seasonal charge adjustment or a full evaporator coil replacement, having the exact .058 expansion orifice on hand prevents the "guessing game" of high subcooling and low suction pressure. Stick with a genuine Nordyne replacement part to ensure the system reaches its rated BTU capacity without compromising the compressor or localized oil return.

Key Benefits:
  • Precise Refrigerant Metering: Calibrated to a .058-inch diameter to ensure accurate flow control and optimal superheat.
  • OEM Compatibility: Designed specifically for Nordyne and Miller HVAC equipment to maintain factory performance standards.
  • High-Durability Construction: Machined from professional-grade materials to withstand high-pressure R-410A or R-22 environments.
  • Simplified Serviceability: Easy to inspect or swap during routine maintenance or when troubleshooting metering restrictions.
Common Questions:
  • How do I know if the #58 orifice is restricted? If you observe high subcooling at the condenser but high superheat at the evaporator, you likely have a restriction at the orifice plate or the liquid line drier.
  • Can I use this orifice for both R-22 and R-410A systems? Compatibility depends on the specific indoor coil and outdoor unit match-up; always verify the required piston size on the outdoor unit’s rating plate.
  • What happens if I install a larger orifice by mistake? An oversized orifice will overfeed the evaporator, leading to low superheat and the potential for liquid slugging back to the compressor.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$3.30

Original: $9.44

-65%
Nordyne 664058 Orifice—

$9.44

$3.30

Product Information

Shipping & Returns

Description

When you are dialing in a Nordyne or Miller split system, the Nordyne 664058 is the specific .058 restrictor orifice required to maintain precise refrigerant metering. As a veteran in the field, you know that using the wrong flow restrictor #58 results in immediate superheat issues, either flooding the evaporator or starving the coil. This piston-style metering device is engineered for specific tonnage and SEER pairings, ensuring the pressure drop across the liquid line stays within OEM parameters. Fabricated from high-grade brass to resist pitting and debris accumulation, this HVAC orifice plate provides the reliable, fixed-metering performance necessary for systems where a TXV is not utilized. Whether you are performing a seasonal charge adjustment or a full evaporator coil replacement, having the exact .058 expansion orifice on hand prevents the "guessing game" of high subcooling and low suction pressure. Stick with a genuine Nordyne replacement part to ensure the system reaches its rated BTU capacity without compromising the compressor or localized oil return.

Key Benefits:
  • Precise Refrigerant Metering: Calibrated to a .058-inch diameter to ensure accurate flow control and optimal superheat.
  • OEM Compatibility: Designed specifically for Nordyne and Miller HVAC equipment to maintain factory performance standards.
  • High-Durability Construction: Machined from professional-grade materials to withstand high-pressure R-410A or R-22 environments.
  • Simplified Serviceability: Easy to inspect or swap during routine maintenance or when troubleshooting metering restrictions.
Common Questions:
  • How do I know if the #58 orifice is restricted? If you observe high subcooling at the condenser but high superheat at the evaporator, you likely have a restriction at the orifice plate or the liquid line drier.
  • Can I use this orifice for both R-22 and R-410A systems? Compatibility depends on the specific indoor coil and outdoor unit match-up; always verify the required piston size on the outdoor unit’s rating plate.
  • What happens if I install a larger orifice by mistake? An oversized orifice will overfeed the evaporator, leading to low superheat and the potential for liquid slugging back to the compressor.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

You may also like

NEW
Thumbnail 1

Nordyne 01-0271 Run Capacitor

$10.84

NEW
Thumbnail 1

Nordyne 669772 TXV

$101.80

-65%NEW
Thumbnail 1

Nordyne D07483R Blower Housing

$178.13

$62.35

NEW
Thumbnail 1

Nordyne 624689R Interface Module

$189.19

-65%NEW
Thumbnail 1

Nordyne 1034994R Fan Grill

$60.79

$21.28

-65%NEW
Thumbnail 1

Nordyne M0090927R Motor

$550.64

$192.72

NEW
Thumbnail 1

Nordyne 922022 Fan Motor

$593.13

NEW
Thumbnail 1

Nordyne D07484R Blower Housing Assy

$167.45

NEW
Thumbnail 1

Nordyne 01-0024 Run Capacitor

$4.39

NEW
Thumbnail 1

Nordyne 669404R Top Grille

$66.04

NEW
Thumbnail 1

Nordyne 622687 Motor

$471.54

-65%NEW
Thumbnail 1

Nordyne 1036349R Latch

$23.67

$8.28

Nordyne 664058 Orifice | GSIstore