Laars Heating Systems 2400-592 Pump Assembly

Laars Heating Systems 2400-592 Pump Assembly

The Laars Heating Systems 2400-592 Pump Assembly is a precision-engineered inline circulator pump specifically configured for Laars EBP/EDP 110 Series boilers. Designed to maintain optimal flow rates in hydronic heating circuits, this 1/25 HP 3450 RPM motor assembly provides a reliable head range of 0 to 15 feet. The cast iron construction ensures housing integrity under thermal stress, while the 2-inch flanged ends allow for rapid field replacement and secure, leak-proof integration into existing piping. Utilizing a high-torque sleeve bearing motor, this centrifugal pump is built for continuous duty cycles in commercial and industrial environments where consistent fluid circulation is critical for boiler efficiency.

Technical Benefits for Contractors:

  • OEM Compatibility: Direct-fit replacement for Laars 2400-592, ensuring electrical and mechanical alignment without modification.
  • Heavy-Duty Housing: Rugged cast iron pump body stands up to system particulates and high-temperature hydronic fluid.
  • Maintenance Efficient: The flanged inline design allows for servicing or motor replacement without disturbing the main piping.
  • Reliable Flow: Engineered for the specific resistance curves of EBP/EDP series heat exchangers to prevent short-cycling.

Common Technical Questions:

Is the 2400-592 compatible with potable water systems?
No, the cast iron pump body is designed for closed-loop hydronic heating applications. For domestic hot water (DHW) loops, a bronze or stainless steel assembly is required to prevent corrosion.

What is the flange-to-flange dimension for this circulator?
Standard installation for the Laars 2400-592 utilizes a 6-3/8 inch port-to-port dimension, common for 1/25 HP inline residential and light commercial pumps.

Does this assembly include the flange gaskets?
While this is a complete pump assembly, it is recommended to inspect and replace the 2-inch flange gaskets during installation to ensure a positive seal at high operating pressures.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$111.23

Original: $317.81

-65%
Laars Heating Systems 2400-592 Pump Assembly

$317.81

$111.23

Product Information

Shipping & Returns

Description

The Laars Heating Systems 2400-592 Pump Assembly is a precision-engineered inline circulator pump specifically configured for Laars EBP/EDP 110 Series boilers. Designed to maintain optimal flow rates in hydronic heating circuits, this 1/25 HP 3450 RPM motor assembly provides a reliable head range of 0 to 15 feet. The cast iron construction ensures housing integrity under thermal stress, while the 2-inch flanged ends allow for rapid field replacement and secure, leak-proof integration into existing piping. Utilizing a high-torque sleeve bearing motor, this centrifugal pump is built for continuous duty cycles in commercial and industrial environments where consistent fluid circulation is critical for boiler efficiency.

Technical Benefits for Contractors:

  • OEM Compatibility: Direct-fit replacement for Laars 2400-592, ensuring electrical and mechanical alignment without modification.
  • Heavy-Duty Housing: Rugged cast iron pump body stands up to system particulates and high-temperature hydronic fluid.
  • Maintenance Efficient: The flanged inline design allows for servicing or motor replacement without disturbing the main piping.
  • Reliable Flow: Engineered for the specific resistance curves of EBP/EDP series heat exchangers to prevent short-cycling.

Common Technical Questions:

Is the 2400-592 compatible with potable water systems?
No, the cast iron pump body is designed for closed-loop hydronic heating applications. For domestic hot water (DHW) loops, a bronze or stainless steel assembly is required to prevent corrosion.

What is the flange-to-flange dimension for this circulator?
Standard installation for the Laars 2400-592 utilizes a 6-3/8 inch port-to-port dimension, common for 1/25 HP inline residential and light commercial pumps.

Does this assembly include the flange gaskets?
While this is a complete pump assembly, it is recommended to inspect and replace the 2-inch flange gaskets during installation to ensure a positive seal at high operating pressures.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

You may also like

NEW
Thumbnail 1

Laars Heating Systems RW2002300 Hot Surface Ignitor

$110.37

NEW
Thumbnail 1

Laars Heating Systems R0491300 Ignition Module

$252.70

-65%NEW
Thumbnail 1

Laars Heating Systems 2400-526 Ignitor/Flame Sensor & Gasket

$197.60

$69.16

-65%NEW
Thumbnail 1

Laars Heating Systems E2313900 Ignition Module

$405.57

$141.95

-65%NEW
Thumbnail 1

Laars Heating Systems T2017100 Front Tile

$82.59

$28.91

-65%NEW
Thumbnail 1

Laars Heating Systems T2017200 Tile

$58.83

$20.59

-65%NEW
Thumbnail 1

Laars Heating Systems T2016600 Tile

$69.27

$24.24

-65%NEW
Thumbnail 1

Laars Heating Systems RA2108500 Blower Kit

$2,068.62

$724.02

-65%NEW
Thumbnail 1

Laars Heating Systems R20047801 Burner/Pilot Assembly

$541.92

$189.67

-65%NEW
Thumbnail 1

Laars Heating Systems R20047802 Burner/Pilot Assy

$510.06

$178.52

-65%NEW
Thumbnail 1

Laars Heating Systems R2069700 Blower Assembly

$374.84

$131.19

-65%NEW
Thumbnail 1

Laars Heating Systems T2016800 Front Tile

$59.86

$20.95