🚚 Free Worldwide Shipping on All Orders!Shop Now
Product image 1
HomeStore

Heil Quaker ICP 1178028 Pressure Switch

Heil Quaker ICP 1178028 Pressure Switch

The Heil Quaker ICP 1178028 Pressure Switch is an essential safety component engineered for high-pressure monitoring in refrigeration and HVAC systems. As a genuine OEM replacement part, this switch is designed to protect the system's compressor by interrupting the electrical circuit when discharge pressures exceed safe operating limits. This specific model features a high-limit trip setting of 660 PSI and a reset point of 505 PSI, providing a precise 660-505 PSI pressure range to maintain system equilibrium and prevent catastrophic equipment failure.

Constructed with a rugged 1/2-inch NPT connection, the ICP 1178028 ensures a secure, leak-proof fit for commercial and industrial applications. It is rated for 125VAC at 10A, making it compatible with a wide array of International Comfort Products equipment, including brands like Arcoaire, Comfortmaker, and Heil. For technicians performing HVAC pressure switch troubleshooting, this component provides the high-cycle reliability required to manage condenser fan cycling and high-head pressure protection in demanding environments.

Key Benefits:
  • Precise Pressure Regulation: Features a factory-calibrated 660 PSI cutout and 505 PSI cut-in for consistent system protection.
  • OEM Compatibility: Exact ICP replacement part designed for seamless integration into Heil Quaker and associated branding.
  • Durable Construction: Built to withstand severe industrial conditions with UL and CSA safety certifications.
  • Enhanced System Longevity: Prevents compressor damage by monitoring refrigerant high pressure levels accurately.
Common Questions:
  • What are the trip and reset points for the 1178028? This high-pressure control is calibrated to trip at 660 PSI and reset at 505 PSI.
  • Is this switch compatible with 120V systems? Yes, it features an electrical rating of 125VAC and 10A, suitable for standard control circuits.
  • Can I use this for low-pressure sensing? No, the 1178028 is strictly a high-pressure safety switch; for low-side monitoring, refer to the ICP 1178029.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$17.00

Original: $48.56

-65%
Heil Quaker ICP 1178028 Pressure Switch—

$48.56

$17.00

Product Information

Shipping & Returns

Description

The Heil Quaker ICP 1178028 Pressure Switch is an essential safety component engineered for high-pressure monitoring in refrigeration and HVAC systems. As a genuine OEM replacement part, this switch is designed to protect the system's compressor by interrupting the electrical circuit when discharge pressures exceed safe operating limits. This specific model features a high-limit trip setting of 660 PSI and a reset point of 505 PSI, providing a precise 660-505 PSI pressure range to maintain system equilibrium and prevent catastrophic equipment failure.

Constructed with a rugged 1/2-inch NPT connection, the ICP 1178028 ensures a secure, leak-proof fit for commercial and industrial applications. It is rated for 125VAC at 10A, making it compatible with a wide array of International Comfort Products equipment, including brands like Arcoaire, Comfortmaker, and Heil. For technicians performing HVAC pressure switch troubleshooting, this component provides the high-cycle reliability required to manage condenser fan cycling and high-head pressure protection in demanding environments.

Key Benefits:
  • Precise Pressure Regulation: Features a factory-calibrated 660 PSI cutout and 505 PSI cut-in for consistent system protection.
  • OEM Compatibility: Exact ICP replacement part designed for seamless integration into Heil Quaker and associated branding.
  • Durable Construction: Built to withstand severe industrial conditions with UL and CSA safety certifications.
  • Enhanced System Longevity: Prevents compressor damage by monitoring refrigerant high pressure levels accurately.
Common Questions:
  • What are the trip and reset points for the 1178028? This high-pressure control is calibrated to trip at 660 PSI and reset at 505 PSI.
  • Is this switch compatible with 120V systems? Yes, it features an electrical rating of 125VAC and 10A, suitable for standard control circuits.
  • Can I use this for low-pressure sensing? No, the 1178028 is strictly a high-pressure safety switch; for low-side monitoring, refer to the ICP 1178029.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

You may also like

NEW
Thumbnail 1

Heil Quaker ICP 1172120 Run Capacitor

$21.75

NEW
Thumbnail 1

Heil Quaker ICP 34329501 Motor

$353.95

-65%NEW
Thumbnail 1

Heil Quaker ICP 1193959 Reversing Valve

$138.06

$48.32

-65%NEW
Thumbnail 1

Heil Quaker 1173705 Heater

$62.10

$21.73

-65%NEW
Thumbnail 1

Heil Quaker ICP 1011052 Collector Box

$179.25

$62.74

-65%NEW
Thumbnail 1

Heil Quaker ICP 1186445 Blower Motor

$789.25

$276.24

-65%NEW
Thumbnail 1

Heil Quaker ICP 1097062 Drain Pan

$11,800.00

$4,130.00

-65%NEW
Thumbnail 1

Heil Quaker ICP 1055151 Drain Pan

$93.27

$32.64

-65%NEW
Thumbnail 1

Heil Quaker ICP 24014202 Fan Blade

$130.02

$45.51

-65%NEW
Thumbnail 1

Heil Quaker ICP 1186259 Run Capacitor

$15.45

$5.41

-65%NEW
Thumbnail 1

Heil Quaker ICP 1186255 Run Capacitor

$27.68

$9.69

-65%NEW
Thumbnail 1

Heil Quaker ICP 34335002 Limit Switch

$43.01

$15.05

Heil Quaker ICP 1178028 Pressure Switch | GSIstore