The Heat Controller R68DD0014 Pressure Switch is a critical safety and operational component designed for negative pressure monitoring in residential and light commercial HVAC systems. Calibrated to a precise -.2" WC (Water Column) set point, this diaphragm-actuated switch ensures the draft inducer is venting combustion gases effectively before allowing the ignition sequence to proceed. Engineered for compatibility with Comfort-Aire, Century, and Mortex gas furnaces?specifically models such as the G18D060, G18D070, G18D077, and G18D090?it provides a normally open (N.O.) contact configuration that closes only when the specific vacuum threshold is reached. This furnace air pressure switch features a robust polycarbonate housing and standard 1/4" spade terminals for direct integration into existing control circuits, maintaining system integrity and preventing operation during venting obstructions or inducer failure.

Key Benefits:
  • Precise Pressure Tripping: Fixed -.2" WC set point prevents nuisance tripping while ensuring high-accuracy vacuum sensing.
  • Broad OEM Compatibility: Direct replacement for Mortex and Heat Controller furnace units, facilitating rapid field service.
  • Enhanced Safety Logic: Reliable SPST N.O. operation prevents burner ignition in the event of restricted flue venting or mechanical inducer failure.
  • Professional Grade Construction: Features a durable sensing diaphragm and glass-filled housing for longevity in high-temperature environments.
Common Questions:
  • How do I know if the R68DD0014 is failing? If the inducer motor runs but the ignition sequence does not start, or if your control board flashes a code for "Switch Stuck Open," the pressure switch or the venting system should be tested with a manometer.
  • Can I use a switch with a different WC rating? No. Pressure settings are specific to the heat exchanger and inducer design; installing a switch with a different rating than the -.2" WC specification can result in unsafe operating conditions.
  • Does this switch support positive pressure sensing? While some switches are universal, the R68DD0014 is specifically designed for negative pressure (vacuum) sensing within the burner or inducer housing.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$87.98
Heat Controller R68DD0014 Pressure Switch—
$87.98

Product Information

Shipping & Returns

Description

The Heat Controller R68DD0014 Pressure Switch is a critical safety and operational component designed for negative pressure monitoring in residential and light commercial HVAC systems. Calibrated to a precise -.2" WC (Water Column) set point, this diaphragm-actuated switch ensures the draft inducer is venting combustion gases effectively before allowing the ignition sequence to proceed. Engineered for compatibility with Comfort-Aire, Century, and Mortex gas furnaces?specifically models such as the G18D060, G18D070, G18D077, and G18D090?it provides a normally open (N.O.) contact configuration that closes only when the specific vacuum threshold is reached. This furnace air pressure switch features a robust polycarbonate housing and standard 1/4" spade terminals for direct integration into existing control circuits, maintaining system integrity and preventing operation during venting obstructions or inducer failure.

Key Benefits:
  • Precise Pressure Tripping: Fixed -.2" WC set point prevents nuisance tripping while ensuring high-accuracy vacuum sensing.
  • Broad OEM Compatibility: Direct replacement for Mortex and Heat Controller furnace units, facilitating rapid field service.
  • Enhanced Safety Logic: Reliable SPST N.O. operation prevents burner ignition in the event of restricted flue venting or mechanical inducer failure.
  • Professional Grade Construction: Features a durable sensing diaphragm and glass-filled housing for longevity in high-temperature environments.
Common Questions:
  • How do I know if the R68DD0014 is failing? If the inducer motor runs but the ignition sequence does not start, or if your control board flashes a code for "Switch Stuck Open," the pressure switch or the venting system should be tested with a manometer.
  • Can I use a switch with a different WC rating? No. Pressure settings are specific to the heat exchanger and inducer design; installing a switch with a different rating than the -.2" WC specification can result in unsafe operating conditions.
  • Does this switch support positive pressure sensing? While some switches are universal, the R68DD0014 is specifically designed for negative pressure (vacuum) sensing within the burner or inducer housing.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

You may also like

NEW
Thumbnail 1

Heat Controller 17317000A51872 Remote Control

$16.44

-65%NEW
Thumbnail 1

Heat Controller 11002012A01092 Fan motor

$55.00

$19.25

-65%NEW
Thumbnail 1

Heat Controller 10352033 Cross Flow Fan

$21.92

$7.67

NEW
Thumbnail 1

Heat Controller 12100105000076 Fan Blade

$14.40

-65%NEW
Thumbnail 1

Heat Controller 801120890009 Outdoor Axial Fan

$10.74

$3.76

NEW
Thumbnail 1

Heat Controller 17122000050360 Main Control Board

$401.60

-65%NEW
Thumbnail 1

Heat Controller 11002012001029 Motor

$204.14

$71.45

-65%NEW
Thumbnail 1

Heat Controller 802920890005 Blower Wheel

$74.91

$26.22

NEW
Thumbnail 1

Heat Controller 7606-201 TXV Kit

$169.87

NEW
Thumbnail 1

Heat Controller R18KT0001 Control Board

$257.68

NEW
Thumbnail 1

Heat Controller 11203103000014 Transformer

$14.22

NEW
Thumbnail 1

Heat Controller 8768 Board

$203.60

Heat Controller R68DD0014 Pressure Switch | GSIstore