For service technicians maintaining Carrier, Bryant, or Payne gas-fired equipment, the Carrier LH660004 Pilot Burner Assembly is the direct OEM replacement engineered for precise ignition and flame rectification. This assembly features a robust stainless steel hood design to prevent carbon buildup and ensure a stable pilot flame signal to the integrated flame sensor or thermocouple. It is supplied as a complete kit, including a factory-installed natural gas orifice (7223) and an additional LP conversion orifice (4210), allowing for field flexibility across different fuel types. Designed for gas furnace maintenance and commercial rooftop units, the LH660004 ensures reliable HVAC combustion safety by maintaining proper burner alignment. As a Factory Authorized Part, it meets exact dimensional specifications of 5.9" x 8.9" x 1.2" for a seamless drop-in fit, reducing troubleshooting time and preventing nuisance lockouts attributed to degraded pilot assemblies in HVAC ignition systems.

Key Benefits for the Contractor:

  • Dual-Fuel Compatibility: Includes both 7223 natural gas and 4210 liquid propane orifices to streamline truck stock.
  • OEM Precision: Genuine Carrier replacement part ensures the mounting bracket and hood alignment meet original equipment standards.
  • Enhanced Durability: Constructed with high-grade materials to withstand high-temperature combustion environments without warping.
  • Safety Compliance: Maintains the stable pilot flame necessary for reliable ignition and burner sequencing.

Common Questions:

Does this assembly include the gas orifices for both Natural Gas and Propane?
Yes, this genuine Carrier LH660004 kit comes with the natural gas orifice pre-installed and includes the necessary LP orifice for field conversion in the burner assembly.

What symptom indicates a failing pilot burner?
Frequent ignition failures, yellow/lazy pilot flames, or "no flame detected" error codes often stem from a dirty or corroded pilot burner assembly.

Is the LH660004 compatible with Bryant and Payne units?
Yes, as a Factory Authorized Part, it is the correct replacement for select Carrier, Bryant, and Payne gas-fired furnaces and rooftop units.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$254.62
Carrier LH660004 Pilot Burner Assembly—
$254.62

Product Information

Shipping & Returns

Description

For service technicians maintaining Carrier, Bryant, or Payne gas-fired equipment, the Carrier LH660004 Pilot Burner Assembly is the direct OEM replacement engineered for precise ignition and flame rectification. This assembly features a robust stainless steel hood design to prevent carbon buildup and ensure a stable pilot flame signal to the integrated flame sensor or thermocouple. It is supplied as a complete kit, including a factory-installed natural gas orifice (7223) and an additional LP conversion orifice (4210), allowing for field flexibility across different fuel types. Designed for gas furnace maintenance and commercial rooftop units, the LH660004 ensures reliable HVAC combustion safety by maintaining proper burner alignment. As a Factory Authorized Part, it meets exact dimensional specifications of 5.9" x 8.9" x 1.2" for a seamless drop-in fit, reducing troubleshooting time and preventing nuisance lockouts attributed to degraded pilot assemblies in HVAC ignition systems.

Key Benefits for the Contractor:

  • Dual-Fuel Compatibility: Includes both 7223 natural gas and 4210 liquid propane orifices to streamline truck stock.
  • OEM Precision: Genuine Carrier replacement part ensures the mounting bracket and hood alignment meet original equipment standards.
  • Enhanced Durability: Constructed with high-grade materials to withstand high-temperature combustion environments without warping.
  • Safety Compliance: Maintains the stable pilot flame necessary for reliable ignition and burner sequencing.

Common Questions:

Does this assembly include the gas orifices for both Natural Gas and Propane?
Yes, this genuine Carrier LH660004 kit comes with the natural gas orifice pre-installed and includes the necessary LP orifice for field conversion in the burner assembly.

What symptom indicates a failing pilot burner?
Frequent ignition failures, yellow/lazy pilot flames, or "no flame detected" error codes often stem from a dirty or corroded pilot burner assembly.

Is the LH660004 compatible with Bryant and Payne units?
Yes, as a Factory Authorized Part, it is the correct replacement for select Carrier, Bryant, and Payne gas-fired furnaces and rooftop units.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.