Carrier HH57AC080 Sensor

Carrier HH57AC080 Sensor

The Carrier HH57AC080 Outside Air Temperature (OAT) Sensor is a critical 10 to 20 mA diagnostic and control component designed for Carrier, Bryant, and Payne commercial rooftop units equipped with Economi$er IV systems. Use this sensor to restore or enable outdoor air dry bulb changeover, allowing the controller to determine when ambient conditions are suitable for free cooling. By providing a precise 4-20 mA signal back to the main control board, the HH57AC080 ensures that dampers modulate correctly to minimize mechanical cooling runtime and maintain building setpoints efficiency.

This OEM-grade sensor features 8 selectable temperature changeover setpoints (ranging from 48°F to 78°F) adjustable via onboard dip switches, with a factory default typically set to 63°F. It is a direct-fit replacement for existing dry bulb sensors and can be used to convert enthalpy-based systems to dry bulb control. In differential dry bulb configurations, it works in tandem with an indoor return air sensor to compare airstream temperatures, ensuring the most cost-effective cooling source is prioritized without taxing the compressor.

Key Benefits:
  • Optimized Economizer Logic: Enables precise free cooling based on outdoor dry bulb temperature to reduce energy consumption.
  • Selectable Changeover Points: Features 8 field-adjustable setpoints for tailored performance in diverse climates.
  • Broad Compatibility: Engineered for use with Carrier 50HJ, 48TC, 50TC, and various Economi$er IV equipped rooftop units.
  • Reliable Signal Output: Provides a 4-20 mA linear output for accurate communication with the system controller.
  • Durable Construction: Built to withstand consistent exposure to outdoor environmental conditions within the intake airstream.
Common Questions:
  • Does this replace an enthalpy sensor? Yes, it can be used to convert a single enthalpy setup to dry bulb control by connecting it to the "SO" and "SO+" terminals.
  • Where is this sensor mounted? It is typically installed in the outdoor airstream, often located behind the economizer hood or on the divider plate.
  • What does a 4 mA signal indicate? In this logic, a 4 mA signal usually indicates the outdoor air is above the changeover setpoint, signaling the dampers to maintain a minimum position.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

$33.13

Original: $94.65

-65%
Carrier HH57AC080 Sensor—

$94.65

$33.13

Product Information

Shipping & Returns

Description

The Carrier HH57AC080 Outside Air Temperature (OAT) Sensor is a critical 10 to 20 mA diagnostic and control component designed for Carrier, Bryant, and Payne commercial rooftop units equipped with Economi$er IV systems. Use this sensor to restore or enable outdoor air dry bulb changeover, allowing the controller to determine when ambient conditions are suitable for free cooling. By providing a precise 4-20 mA signal back to the main control board, the HH57AC080 ensures that dampers modulate correctly to minimize mechanical cooling runtime and maintain building setpoints efficiency.

This OEM-grade sensor features 8 selectable temperature changeover setpoints (ranging from 48°F to 78°F) adjustable via onboard dip switches, with a factory default typically set to 63°F. It is a direct-fit replacement for existing dry bulb sensors and can be used to convert enthalpy-based systems to dry bulb control. In differential dry bulb configurations, it works in tandem with an indoor return air sensor to compare airstream temperatures, ensuring the most cost-effective cooling source is prioritized without taxing the compressor.

Key Benefits:
  • Optimized Economizer Logic: Enables precise free cooling based on outdoor dry bulb temperature to reduce energy consumption.
  • Selectable Changeover Points: Features 8 field-adjustable setpoints for tailored performance in diverse climates.
  • Broad Compatibility: Engineered for use with Carrier 50HJ, 48TC, 50TC, and various Economi$er IV equipped rooftop units.
  • Reliable Signal Output: Provides a 4-20 mA linear output for accurate communication with the system controller.
  • Durable Construction: Built to withstand consistent exposure to outdoor environmental conditions within the intake airstream.
Common Questions:
  • Does this replace an enthalpy sensor? Yes, it can be used to convert a single enthalpy setup to dry bulb control by connecting it to the "SO" and "SO+" terminals.
  • Where is this sensor mounted? It is typically installed in the outdoor airstream, often located behind the economizer hood or on the divider plate.
  • What does a 4 mA signal indicate? In this logic, a 4 mA signal usually indicates the outdoor air is above the changeover setpoint, signaling the dampers to maintain a minimum position.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

You may also like

-65%NEW
Thumbnail 1

Carrier LH33WZ009A Electrode Sensor

$58.47

$20.46

-65%NEW
Thumbnail 1

Carrier LH33WZ007 Flame Sensor

$78.45

$27.46

-65%NEW
Thumbnail 1

Carrier LH33WP008 Control Board

$390.05

$136.52

-65%NEW
Thumbnail 1

Carrier LH33JZ050 ReIgnition Coil

$1,254.35

$439.02

-65%NEW
Thumbnail 1

Carrier LH33EP001 Control Board

$449.47

$157.31

-65%NEW
Thumbnail 1

Carrier LH33CZ003 Ignition Control

$169.50

$59.32

-65%NEW
Thumbnail 1

Carrier LH32RF140 Burner Orifice

$5.09

$1.78

-65%NEW
Thumbnail 1

Carrier LH32WB010 Pilot Orifice

$56.57

$19.80

-65%NEW
Thumbnail 1

Carrier LH33WZ016 Ignitor

$69.14

$24.20

-65%NEW
Thumbnail 1

Carrier LH33WZ010 Ignitor

$103.57

$36.25

-65%NEW
Thumbnail 1

Carrier LH33WZ015 Flame Sensor

$72.12

$25.24

NEW
Thumbnail 1

Carrier LH660010 Ignitor Module

$608.11

Carrier HH57AC080 Sensor | GSIstore